But by understanding how these items fit together and what purpose they serve, you can have a successful project. Use the below learning-reinforcement questions to study for the Continuing Education Assessment Exam available online at www.elevatorbooks.com or on page 111 of this issue. Name the principal code other than NEC that pertains to elevator design/installation. What is the definition of the machine room? Why are voltage limitations important? In which areas must live parts be enclosed? Why are feeder demand factors permitted for multiple elevators? It employs specialists in Mobile, Alabama, and has technical and news correspondents around the world. +90 (216) 348 4876, India Office A traction elevator's equipment room is typically located at the top of the building, directly over or adjacent to the shaft. GET YOUR CEUS TODAY, 1998-2021. This will normally require you to vent the room with a fire/smoke damper and include smoke detector signals in the control logic. Flexible cords and cables that are components of listed equipment and used in circuits operating at 30 V (42 VDC) or less are permitted in lengths not to exceed 6 ft., provided the cords and cables are supported and protected from physical damage and are of a jacketed and flame-retardant type. However, when I've put in elevators, NEC seems to always take a back seat to ANSI, which seems . Besides the initial determination requirement of paragraph (c) (1), the "host" employer must comply with the five (5) requirements of paragraph (c) (8) when engaging another employer (contractor) who will have employees in permit spaces under the control of the host employer. Many new buildings are incorporating an elevator design that does not include an equipment room (sometimes called machine room-less elevators). Elevator Pit Drain or Sump Pump | UpCodes The code notes that elevator rails or other hoistway equipment are not to be used as the grounding conductor for lightning-protection systems. Related Code Sections 802.1.8 Indirect/Special Waste, Elevator Pit Drain or Sump Pump Marking the elevator controller short-circuit current rating (SCCR) by the elevator controller manufacturer. PDF C.1 General Requirements for All Elevator Installations In elevators provided with Firefighters' Emergency Operation, a drain or sump pump shall be provided. 354 Morgan Ave. These requirements, found in Article 620 (part of Chapter 6, Special Equipment), are in addition to NEC Chapters 1-3, which stipulate general wiring protocols applicable in most residential, commercial and industrial venues. These 29 CFR 1910.146 (c) (8) requirements are: The two documents are in harmony and should be used in conjunction. It is further stipulated that internal voltages of power-conversion equipment and functionally associated equipment, and the operating voltages of wiring interconnecting the equipment, are permitted to be higher, provided that the equipment and wiring are listed for the higher voltages. Of particular importance is the location of the disconnecting means so it can be found by an individual who may not be familiar with the installation. This is somewhat broader than A17.1-2007/B44-07. endstream
endobj
startxref
These are: remote machine room and control room (for elevator and dumbwaiter), and remote machinery space and control space (for elevator and dumbwaiter). The action you just performed triggered the security solution. The two primary hazards are fire and electric shock or arc flash, although there are others. PK ! The electrical energy does not traverse the human body, but proximity to the explosion means severe injury is possible from the intense heat and concussive shockwave. If a smoke detector goes into alarm, it signals the elevator to go into Fire Recall Function, at which point the controller directs the elevator cab to travel to its pre-programmed designated landing, open its doors, and remain stopped there until the alarm clears. Pit light with guard (ten foot candles min. You must run a separate insulated grounding conductor with the feeder conductors from the electrical source to the elevator controller. or larger is permitted to be installed in lengths in excess of 6 ft. Where motor-generators, machine motors or pumping-unit motors and valves are located adjacent to or underneath control equipment and provided with extra-length terminal leads not exceeding 6 ft. in length, such leads are permitted to be extended to connect directly to controller terminal studs without regard to carrying-capacity requirements. Something went wrong. Such design innovations require sophisticated wiring strategies. In many cases, the overcurrent protective devices that are suitable for this level of protection are current-limiting fuses rather than a traditional circuit breaker. hb``` ea``j~p2nfH
'xXg00,/(_ Iq8PDdg-~ s$!XI;Fn0vu
`h`R 1y
0B.":9.@, e`xI;=7O3fvbb8:SC;%O*20] +90 (216) 348 4876, India Office NEC 2011 also addresses branch circuits for machine room or control room/machinery space or control-space lighting and receptacles. GFI Receptacles: GFI receptacles shall be required in all elevator machine rooms, machinery spaces and elevator pit areas. The light switch in the pit must be mounted 42 in. As they review the plans and the construction site, they may have conflicting interpretations or requirements. 3016. Pits for Elevators. - California Department of Industrial Relations The electrical system designer calculates the maximum available fault current at the elevator controller. 1. Second, it must be configured so as to eliminate any chance of tangling or chafing against the inner surface of the hoistway or items mounted on it. (To design and install an elevator for a Class I, Division 1 location would be quite an undertaking.). 836 Troy Schenectady Road Latham, NY 12110 . In hoistways not longer than 6 ft., these additional wiring methods are permitted: A sump or oil-recovery pump located in the pit is permitted to be cord connected. He participates in IEEE (Senior Member) with Industrial and Commercial Power Systems, NEMA (member of the Codes & Standards Committee), NFPA (committee member for NEC CMP-13 and NFPA 79), UL (508/60947 and 508A) and IAEI activities. Receptacle for pumps located in the pit shall be a single non-GFCI and shall be located 6 inches above the lowest landing. In addition, requirements for selective coordination and shunt tripping should be complied with as needed for the installation. Get more of Elevator World. For just $7.99 per month, you can gain access to more than 5,000 articles from all Elevator World Publications, this includes EW Global, EW Europe, EW India, EW Middle East, EW Turkey, and EW UK. This device must be either a fused disconnect or a circuit breaker because ANSI/ASME A17.1 requires you to install an additional overcurrent protection device (OCPD) in the elevator equipment room. As such, elevator controller manufacturers should make the effort to rethink their designs to avoid costly system design changes. The sum of the cross-sectional area of the individual conductors in raceways is not to exceed 40% of the interior cross-sectional area of the raceway, except as permitted for wireways. (g) Stop Switch in Pits. of the sprinkler heads. Similarly, the integrity of the traveling cable is emphasized. It is noted that the article covers the installation of electrical equipment and wiring for elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. Section 620.85, GFCI Protection for Personnel, provides that 125-V, single-phase, 15- and 20-amp receptacles installed in pits, hoistways, machinery spaces, machine rooms, escalators and moving walks, and on elevator car tops are to be GFCIs. Elevator Pit Sump Pump Electrical Requirements If the disconnecting means is an integral part of the motor controller, it is to be operable without requiring opening of the enclosure. Fuses: Verify that the correct size, type and capacity are installed. Many people use portable generators until power is restored. Acceptable types of wire for this application are given in Table 400.4, which occurs in an earlier chapter and lists various types of elevator cable for lighting and control in both unclassified and hazardous locations. The floor specified as the designated landing, which must be approved by the Fire Marshal, is usually the floor on grade level so passengers can quickly exit to the outside. Metal grating shall be installed over the hole that sits flush with the pit floor. A clean and dry elevator pit and machine/control room provided (ASME A17.1 Rule 2.1.2) Machine/control room meets manufacturer's requirement of preserving ambient temperature control and humidity (ASME A17.1 Rule 2.7.9) Elevator floor covering installed with appropriate smoke and flame spread (ASME A17.1 Rule 2.14.2) Pit drainage must be designed to eliminate a minimum capacity of 3,000 gallons per hour (or 50 GPM) per elevator car. Sign up for our free e-newsletter. The lighting is not to be connected to a GFCI, because the elevator car is not a place that should experience nuisance tripping. GFCIs in Elevator Pits, Receptacles and More Notwithstanding, if sprinklers are installed in hoistways, machine rooms or the like, the disconnecting means is permitted to automatically open the power supply to the affected elevator(s) prior to the application of water. Another important electrical system design consideration for supplying power to multiple elevators is NEC 620.62. NEC Article 0: Elevator art by David Herres Continued. Finally, typical installations and compliance with all these requirements will be discussed. Hydraulic elevators comprise a hydraulic reservoir, pump, cylinder, and controller. This switch will ensure that the elevator won't descend into the elevator pit and allow maintenance people to work safely in the area beneath the cab. above the pit floor, shall: Be weatherproof (NEMA 4). The conduit alone can't act as the grounding means.
Conductors supplying more than one motor, motor controller or power transformer are to have an ampacity not less than the sum of the nameplate current ratings of the equipment plus all other connected loads. NEC articles generally adhere to a template, which greatly aids in navigating and quickly locating mandates as needed for project design or, on an installation level, in the field. First, it is now clear that elevator controllers must be marked by the manufacturer with their SCCR. Traction elevators are typically installed in a bank of elevators where fused switches, or circuit breakers in a panelboard are located in the machine room serving the bank of elevators. Convenience receptacles and lighting for maintenance purposes are required at the base of the pit and, in some instances (elevator manufacturer dependent), at the top of the elevator shaft. It does specify wiring methods allowed, though, in 620. Society of Mechanical Engineers. We shall now take a look at the principle requirements of Article 620, with particular emphasis on wiring requirements for elevator shafts, machine rooms and cars. If elevators are supplied by the emergency, legally required standby or critical operation power systems, then selective coordination is required per the 2017 NEC in 700.32, 701.27 or 708.54. +91 8025357028, 2022 Elevator World, LLC. Generally, it is decreed that the supply voltage is not to exceed 300 V between conductors (allowing for the familiar 240-V concept), although there are exceptions. NEC Article 620 Part V, Traveling Cables, is driven by two major issues. Personal protective equipment (PPE): Use appropriate PPE to protect body parts within the range of 3-16 in. Flexible metal, liquid-tight flexible metal or liquid-tight flexible nonmetallic conduit 3/8 in. This website is using a security service to protect itself from online attacks. As we have seen, a limited number of these are approved for elevator locations car, hoistway, pit and machine room. Since 1953, Elevator World, Inc. has been the premier publisher for the global vertical transportation industry. A separate 120VAC, 15A circuit is required for cab lighting and accessories, and it must have its own local disconnect and OCPD in the equipment room as well. A section on branch circuits for car lighting, receptacles, ventilation, heating and air-conditioning contains a number of important provisions. High-rise buildings pose additional concerns. Article 511 provides the requirements for commercial garages areas used for the storage or repair of self-propelled vehicles that use combustibles (liquid or gas) for power. But, building codes had been in existence for many centuries. The traveling cable, of necessity, is exempted. Follow the manufacturers instructions and precautions. Some elevator controller manufacturers believe this is an issue for the electrical system designer and installer to address and remedy by adding impedance to the system for lowering the available fault current. Good documentation is of key importance to recalling what decisions were made and why. For elevators that regenerate power back into a power source unable to absorb the regenerative power under overhauling elevator load conditions, a means to absorb this power is to be provided. The most complex of these is the elevator. To achieve flexibility and endurance, traveling cable is more finely stranded and, where possible, separated into discrete conductors. The code exempts some fairly broad areas where compliance is not expected. [emailprotected] Lights and convenience outlets in elevator pits shall be installed to comply with the requirements of CCR, Title 24, Part 3, Article 620. If you specify a rescuvator, you must also specify a disconnect switch with an auxiliary contact that opens when the disconnect arm moves to the open position, but stays closed when the OCPD trips. A second door is required if the equipment is rated over 1200 amps and over 6 ft. wide. Working spaces for electrical equipment that may have to be examined, adjusted, serviced or maintained is required in all occupancies in an earlier NEC section, 110.26(A). NEC Guidelines on Commercial Garages. With heavy use on a hot day, the oil can overheat, causing elevator shutdown. Main feeders that supply elevator power must be kept outside the hoistway unless one of the following applies: Feeders for elevators are permitted within an existing hoistway (provided they are not spliced within the hoistway) by special permission of the AHJ. The traveling cable, moreover, may be run without raceway from inside the hoistway to elevator-controller enclosures and to the elevator car and machine room and similar locations outside the hoistway for a distance not exceeding 6 ft. The panel further clarified that the marked SCCR value must be adequate for the available fault current to ensure a safe installation. NEMA 4 : All electrical equipment, located less than 1225 mm (48 in.) Years may lapse between the design and installation stages of a project. The pump sends hydraulic fluid from the reservoir to the cylinder, buried deep below the elevator shaft. DOCX 26 80 00 - Elevator Electrical Requirements - University of Illinois It begins by considering metal and nonmetallic wireways. To avoid this situation, designers can specify elevator controls with a safety feature commonly called a rescuvator. CLAIMED . Therefore, elevator equipment rooms must maintain a temperature between 50F and 90F. Accordingly, for this application, the minimum size is reduced to 20 AWG for lighting circuits. From the website: Mohawk Lifts offers car lifts and auto lifts for purchase, including 2 post lifts, 4 post lifts, storage lifts, heavy duty mobile column lifts, parallelogram lifts, and other specialty items. This is typically accomplished via a shunt trip device. A further requirement concerns elevator-car air-conditioning and heating. Required lighting shall not be connected to the load side of a ground-fault circuit interrupter. (Cross-sectional areas of conductors are given in Chapter 9, Tables 5 through 8. There are options available to achieve this depending upon the customers needs. This is because the material may contribute fuel to a fire that has originated elsewhere. Installing electrical equipment where its SCCR is less than the available short-circuit current creates serious safety hazards. In order to aid enforcement, the panel additionally required marking the available fault current at the elevator controller. The sump pump/drain shall have the capacity to remove a minimum of 11.4 m. 3 /h (3,000 gal/h) per elevator. This room is to be secured against unauthorized access (kept locked). The conductors must be in their original sheaths or grouped together and taped or corded. ,l7CLHmcX9*F -{Q|^"XL`b1y]$,y *R/2Rn{\xG
L*vMP.uKW,)68]Y}+ FYS1B=Q0S>Hc Hoistway door interlock wiring from the riser must be flame retardant and have insulation suitable for a temperature not less than 200C (392F), much higher than that required for most raceway or cable applications. Cloudflare Ray ID: 7a2fbe9ebd7e2fe8 : inspecting; troubleshooting; observing; etc.) Cross-sectional areas of wireways are found by multiplying the two interior dimensions.) The basic rule for conductor fill of a metal wireway, as given in Article 376, is that the sum of the cross-sectional areas of all contained conductors at a cross section of a wireway is not to exceed 20% of the interior cross-sectional area of the wireway. In this case, it may be best if the elevator controller manufacturer does not include the elevator disconnecting means (often offered as a circuit breaker) but instead have the installer provide a separate fused disconnect to comply with NEC 620.51(A) and also achieve a high SCCR for the elevator controller when fuses are provided as specified by the elevator controller and marked on the elevator controller nameplate. You are seeing this message for one of three reasons: You have reached your limit of free content. So, we see that for elevator work, greater fill is allowed. You'll be responsible for specifying the items related to the fire alarm and some controls, as well as supplying lighting and power to the equipment room and elevator pit. Similar provisions are attached to elevator-car heating and air-conditioning disconnecting means, and to other utilization equipment. PDF NEC Article 0: Elevator art A different occurrence involves exposure to the explosive blast when there is a line-to-line or line-to-ground arc blast. If your specifications require a vent at the top of the shaft for venting smoke, you must provide a key switch with a pilot light to control that vent. Louisiana State Uniform Construction Code Council adopts the 2014 NEC, Basic three-phase power measurements explained, Safety After the Storm Operating Portable Generators. The light switch shall be located so to be accessible from pit access door. Cylinders in hydraulic elevators usually aren't suitable for buildings taller than five stories. Your Quick and Easy Elevator Code Checklist | Kings III 2. In the event of a breakdown, that phone must automatically call a location staffed 24 hours a day. In addition, the shunt-trip voltage must also be monitored by the Fire Alarm System. As recommended in NFPA 70E, the National Elevator Industry, Inc. (NEII) commissioned an arc-flash hazard analysis (in compliance with IEEE Standard 1584-2002 for procedures for calculating the incident energy of the arc flash) by an independent consultant to determine at what level an arc-flash hazard exists to employees who work on energized elevator equipment. NEC 2011 Article 620.21(2)(b) states that hard-service cords and junior hard-service cords that conform to the requirements of Article 400 (Table 400.4) are permitted as flexible connections between the fixed wiring on the car and devices on the car doors or gates. The electrical system designer needs to communicate this information to the person responsible for specifying the elevator controller, which is most often the architect.